240V Radiant Floor Heat System Electric Cable Tile Warm Heated All Size w/Thermo
Electric Floor Heating Cable with Programmable Touch Screen Thermostat. It is made from the highest quality materials and is guaranteed with a 25 Year Warranty. EVERYTHING YOU NEED IS INCLUDED: WARMING SYSTEMS HEATING CABLE Floor Heating Cable The Electric Floor Heating Cable consists of a spool of heating cable. Simply run the cable 3″ apart across the area to heat using the cable guides to secure to the floor and run the cold lead up the wall to the electrical box. These heating systems are ideal for odd shaped areas or to heat around objects. The RED HEATING ELEMENT CAN NOT BE CUT, so be sure to accurately measure the space you are heating.TOUCH SCREEN PROGRAMMABLE THERMOSTAT with SENSOROJ MICROLINE Model # UDG4-4999This programmable Touch Screen floor sensing thermostat includes the floor sensor, is designed to work with 120V or 240V electric floor heating systems, and has built-in GFCI protection.This state of the art touchscreen thermostat is extremely user friendly with sleek design and intuitive control designed for easy installation. The 3.5″ smart control color touchscreen is easy to navigate making programming this thermostat simple to do.The floor sensor is included with the thermostat and runs down the wall and into the heated area to give an accurate floor temperature reading. The sensor probe is installed in between the heating elements.The thermostat also has a built in “Ambient” temperature sensor that allows for dual temperature control. INSTALLATION MONITORThe Installation Monitor measures continuity of the heating system during installation and will alarm if the heating system gets damaged. It will give you peace of mind while installing the floor warming system. Connect the system leads to the monitor prior to installation. The monitor will “scream” a warning in the event the heating element is cut or damaged allowing you to make any necessary repairs before the heating system is embedded in mortar. If the alarm sounds, stop work and consult the operation manual. We still recommend checking the ohms of the floor heating system with a multimeter before, during, and after installation.Red light and alarm indicates lead wires have come loose from the terminals or damage has occurred to the heating systemCABLE GUIDESDesigned for fast installation of the the heating cable, simply loop the floor heating cable around the guide as you lay the cable system across the subfloor.Secure the cable guides according to the planned layout using screws, nails, adhesive or glue approved for use with the given subfloor. The heating element should be spaced 3″ apart across the area to be heated. Cable guides should be run perpendicular to heating cables. The heating cables should have a minimum distance of 2″ from walls and objects. Spacing between cable guides should not exceed 36″ in distance. Secure the heating element to cable guides by wrapping the wire around the stud. Maintain moderate tension of cable throughout installation. Do not twist heating element and keep the minimum bending radius of the cable to 1″.Cable guides are 12″ long and can be cut to length. Includes enough cable guides for cable heating system.Video will open in a new window Listing and template services provided by inkFrog
HVAC Mini Split Condensate Pump, 20M High Lift, 100-240V, Ultra Quiet 16dB, Soft
The Soft-Start technology initiates the motor gently to eliminate sudden vibration noise, while the automatic variable flow (20-40L/h) dynamically adjusts speed based on condensation levels. Compatible with units up to 46kW (157,000 Btu/h), it handles demanding HVAC needs with ease.
Dayton 24N065 Double Panel Vertical Wall Shutter Motor, 100-240V, 50/60 Hz
BRAND NEW SEALED BOX Dayton 24N065 Double Panel Vertical Wall Shutter Motor, 100-240V, 50/60 Hz Phase 1 Amps 2/1.3 Height (In.) 6 1/2 in Width (In.) 4 in Depth (In.) 6 1/4 in Mounting Position Vertical For Use With : Double Panel Wall Shutters Includes: Installation Hardware
MSKOTOAS MS-PWB Spray Evaporative Condensate Pump 3.3 GPH 100-240V
Aube by Honeywell PB100-240S3 Non-Programmable Line Voltage Thermostat 240V
Maximum Load: 1500 W @ 120 VAC, 3000 W @ 240 VAC (Non-inductive). – Minimum Load: 2 A.
Durablow TR2004 Fireplace Remote Control Kit Thermostat Timer Backlit 100-240V
No Batteries Needed for Receiver 100–240VAC Powered Receiver: Connects directly to power so you can avoid frequent battery changes. Comfort You Don’t Have to Adjust Constantly Built-In Thermostat: Turns your fireplace ON/OFF automatically so you can maintain your desired room temperature.
VIQUA VA-CTRL Replacement UV Controller For Arros Series 100–240V original oem
Needs new UV Lamp. The lamp part number VA09LU
Trane D803351P02 Power Supply With Back Plane HAC-60AP 100-240V 1.5A CNT06628
Item is in new old stock condition. This item was removed from a new furnace unit. It is not used, but was previously factory installed. See photos for detail and condition.Could be found in: AAM7A0A24H21SAA AAM7A0B30H21SAA AAM7A0C36H31SAA AAM7A0C42H31SAA AAM7A0C48H41SAA AAM7A0C60H51SAA AAM8A0A24V21CAA AAM8A0B30V21CAA AAM8A0C36V31CAA AAM8A0C42V31CAA AAM8A0C48V41CAA AAM8A0C60V51CAA TAM7A0A24H21EAA TAM7A0A24H21SAA TAM7A0A24H21SBA TAM7A0A24H21SBB TAM7A0A24H21SCB TAM7A0A24H21SDB TAM7A0B30H21EAA TAM7A0B30H21SAA TAM7A0B30H21SBA TAM7A0B30H21SBB TAM7A0B30H21SCB TAM7A0B30H21SDB TAM7A0C36H31EAA TAM7A0C36H31SAA TAM7A0C36H31SBA TAM7A0C36H31SBB TAM7A0C36H31SCB TAM7A0C36H31SDB TAM7A0C42H31EAA TAM7A0C42H31SAA TAM7A0C42H31SBA TAM7A0C42H31SCA TAM7A0C42H31SDA TAM7A0C48H41EAA TAM7A0C48H41SAA TAM7A0C48H41SBA TAM7A0C48H41SCA TAM7A0C48H41SDA TAM7A0C60H51SAA TAM7A0C60H51SBA TAM7B0C60H51EAA TAM7A0C60H51SAA TAM7A0C60H51SBA TAM7B0C60H51EAA TAM7B0C60H51SAA TAM7B0C60H51SBA TAM7B0C60H51SCB TAM8A0A24V21CAA TAM8A0A24V21CBA TAM8A0A24V21CBB TAM8A0A24V21CCB TAM8A0B30V21CAA TAM8A0B30V21CBA TAM8A0B30V21CBB TAM8A0B30V21CCB TAM8A0C36V31CAA TAM8A0C36V31CBA TAM8A0C36V31CBB TAM8A0C36V31CCB TAM8A0C42V31CAA TAM8A0C42V31CBA TAM8A0C42V31CCA TAM8A0C60V51CAA TAM8A0C60V51CBA TAM8B0C60V51CAA TAM8B0C60V51CBA TAM8C0A24V21CAA TAM8C0A24V21CBA TAM8C0A24V21EAA TAM8C0B30V21CAA TAM8C0B30V21CBA TAM8C0B30V21EAA TAM8C0C36V31CAA TAM8C0C36V31CBA TAM8C0C36V31EAA TAM8C0C42V31CAA TAM8C0C42V31CBA TAM8C0C42V31EAA TAM8C0C48V41CAA TAM8C0C48V41CBA TAM8C0C48V41EAA TAM8C0C60V51CAA TAM8C0C60V51CBA TAM8C0C60V51EAA TAMGA0A24H21ECA TAMGA0A24H21SAA TAMGA0A24H21SBA TAMGA0A24H21SCA TAMGA0C36H31ECA TAMGA0C36H31SAA TAMGA0C36H31SBA TAMGA0C36H31SCA TAMGA0C48H41ECA TAMGA0C48H41SAA TAMGA0C48H41SBA TAMGA0C48H41SCA TAMGA0C60H51ECB TAMGA0C60H51SAA TAMGA0C60H51SBA TAMGA0C60H51SCB
Advantage Controls NANO-F2 100-240VAC – New in Factory Sealed Box
Mini Split Condensate Pump for HVAC 100-240V Automatic Condensation Drain Rem…
Efficient Drainage: This automatic condensate pump features an efficient thermally protected motor, providing quick draining and ultra-silent operation (25 dB) with max.flow 5.7 GPH or max.head 60FT.