10KW On Grid Wind Turbine Inverter 220V 380V 50Hz Power Grid-Tie MPPT w/ RS485

This grid tie inverter is for wind turbine power generation. The inverter input is 3 phase AC, not DC. The inverter output is for 220V single phase grid OR 380V 50Hz/60Hz Three phase grid . Before placing the order, please provide the seller the data of the generator (rated power, rated RPM, rated voltage, magnet pairs), thanks. System Composition The system mainly includes: wind turbine, lightning protector 1 in wind turbine side, electromagnetic brake system, AC filter in wind turbine side, rectifier boost voltage, dump load circuit, inverting bridge, AC filter in inverter side, common mode filter, AC breakers, lightning protector 2 in grid side, and single-phase 230V grid. Hardware Function Introduction Lightning protector: the lightning protection device at the input and output side of the machine. Electromagnetic brake: the machine can start electromagnetic brake to brake the wind turbine when rotational speed is over, inverter output power is over, the temperature is over. AC filter: The ripple and DC components in AC voltage are filtered out, and the AC voltage is transformed into a smooth, harmonic waveform which satisfying the requirements. Rectifier boost circuit: Transform and boost the three-phase AC voltage generated by wind turbine to required DC voltage. Dump load circuit: Redundant power is released by dump load by PWM control. Inverting bridge: transform DC to AC Common mode filter: suppress EMI interference in the circuit. AC breakers: Cut off the connection between grid and inverting bridge during inverter fault or standby to avoid rectification flow backward Features Wind power Controller&Inverter integrated machine Support wide range voltage input MPPT included, and track point settable Complete protection functions. Model WWGI100 Wind Turbine Input Rated input power 10kW Max. input power 11kW Rated input voltage 220Vac Manual brake Keep pressing the button for 5s to unload completely, and then recover by pressing it for another 5s. Switch “ON” the brake switch Brake by over wind speed(optional) 18m/s (0~30m/s settable), it dumps load completely when reached the set wind speed, and recover automatically after working 10mins and wind speed is less than 15m/s. Brake by over rotational Speed(optional) 500r/min(factory default,0~1000r/min settable) Unload completely when reached the set rotational speed, and recover automatically after 10mins. AC Output Grid Type Single-phase Rated output power 10kW Rated Grid voltage 220Vac Grid voltage range 200~260Vac Rated Grid frequency 50Hz Work frequency range 49Hz~51Hz Rated output current 22.7A Thdi <5% (at rated power) Protection Functions AC output overvoltage/ undervoltage protection YES AC output over frequency /underfrequency protection YES AC short circuit protection YES Surge protection YES Anti-islanding protection YES Over-temperature protection YES Lightning protection YES General Parameters Display mode LED Display information dump load, grid state, wind generator state, faults Monitoring contents wind rotate speed, wind power, AC output voltage /current/power, and fault code Efficiency >93% Ambient temperature -20℃~+40℃ Humidity 0%~90%, no condensing Noise ≤65dB Cooling mode Forced air cooling Cover protection class IP54 Product dimension (W*H*D) 370×545×185mm Product net weight 19kg Dump load dimension(W*H*D) 390×730×190mm Dump load net weight 19kg Note: Part of parameters can be adjusted according to customer’s specific demand. Model WWGIT100 Wind Turbine Input Rated input power 10kW Max. input power 11kW Rated input voltage 380Vac Manual brake Keep pressing the button for 5s to unload completely, and then recover by pressing it for another 5s. Switch “ON” the brake switch Brake by over wind speed(optional) 18m/s (0~30m/s settable), it dumps load completely when reached the set wind speed, and recover automatically after working 10mins and wind speed is less than 15m/s. Brake by over rotational Speed(optional) 500r/min(factory default,0~1000r/min settable) Unload completely when reached the set rotational speed, and recover automatically after 10mins. AC Output Grid Type Three-phase Rated output power 10kW Rated Grid voltage 380Vac Grid voltage range 320~420Vac Rated Grid frequency 50Hz Work frequency range 49Hz~51Hz Rated output current 8A Thdi <5% (at rated power) Protection Functions AC output overvoltage/ undervoltage protection YES AC output over frequency /underfrequency protection YES AC short circuit protection YES Surge protection YES Anti-islanding protection YES Over-temperature protection YES Lightning protection YES General Parameters Display mode LED Display information dump load, grid state, wind generator state, faults Monitoring contents wind rotate speed, wind power, AC output voltage /current/power, and fault code Efficiency >93% Ambient temperature -20℃~+40℃ Humidity 0%~90%, no condensing Noise ≤65dB Cooling mode Forced air cooling Cover protection class IP54 Product dimension (W*H*D) 370×545×185mm Product net weight 19kg Dump load dimension(W*H*D) 390×730×190mm Dump load net weight 19kg Note: Part of parameters can be adjusted according to customer’s specific demand. Please connect those parts according to the order of ①②③④, and notice the following items. Connect two output lines of dump load to the unload terminals “R” “R” of the machine. Connect “L” “N” and earth wire of grid to the terminals “L” “N” and “” on the machine relatively. When wind turbine is still or running in a low speed, connects its output line to the “WIND INPUT” terminal on the machine. Connect communication device to the relative communication port if there is a communication device. Check all the connection to make sure they are connected rightly and tightly. Note: Please measure the voltage and frequency of the grid before connect the system to the grid. AC “L” “N” cannot be connected to the earth wire terminal, or the machine will be damaged permanently. The switch should be at “BRAKE” status while installation, and changed to “RUN” status when it works. Fault code Analysis Possible solutions 1 Grid is not normally connected. Grid voltage or frequency is abnormal Check the details from the monitoring software. 2 Inverting circuit soft over current protection Check the wiring connection on the AC side circuit after ensuring the machine is disconnected with any power supply. 3 Bus overvoltage protection Please connect Win Power 4 over temperature protection once the inverting module temperature recovers to normal, the machine will clear the fault itself. 5 IPM protection for the inverting side Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 6 Rectifying circuit soft over current protection Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 7 IPM protection for rectifying side Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 8 Wind voltage is higher than bus voltage fault protection point. Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power.

10000W On Grid Wind Turbine Inverter 220V 380V 50Hz Power Grid-Tie MPPT w/ RS485

This grid tie inverter is for wind turbine power generation. The inverter input is 3 phase AC, not DC. The inverter output is for 220V single phase grid OR 380V 50Hz/60Hz Three phase grid . Before placing the order, please provide the seller the data of the generator (rated power, rated RPM, rated voltage, magnet pairs), thanks. System Composition The system mainly includes: wind turbine, lightning protector 1 in wind turbine side, electromagnetic brake system, AC filter in wind turbine side, rectifier boost voltage, dump load circuit, inverting bridge, AC filter in inverter side, common mode filter, AC breakers, lightning protector 2 in grid side, and single-phase 230V grid. Hardware Function Introduction Lightning protector: the lightning protection device at the input and output side of the machine. Electromagnetic brake: the machine can start electromagnetic brake to brake the wind turbine when rotational speed is over, inverter output power is over, the temperature is over. AC filter: The ripple and DC components in AC voltage are filtered out, and the AC voltage is transformed into a smooth, harmonic waveform which satisfying the requirements. Rectifier boost circuit: Transform and boost the three-phase AC voltage generated by wind turbine to required DC voltage. Dump load circuit: Redundant power is released by dump load by PWM control. Inverting bridge: transform DC to AC Common mode filter: suppress EMI interference in the circuit. AC breakers: Cut off the connection between grid and inverting bridge during inverter fault or standby to avoid rectification flow backward Features Wind power Controller&Inverter integrated machine Support wide range voltage input MPPT included, and track point settable Complete protection functions. Model WWGI100 Wind Turbine Input Rated input power 10kW Max. input power 11kW Rated input voltage 220Vac Manual brake Keep pressing the button for 5s to unload completely, and then recover by pressing it for another 5s. Switch “ON” the brake switch Brake by over wind speed(optional) 18m/s (0~30m/s settable), it dumps load completely when reached the set wind speed, and recover automatically after working 10mins and wind speed is less than 15m/s. Brake by over rotational Speed(optional) 500r/min(factory default,0~1000r/min settable) Unload completely when reached the set rotational speed, and recover automatically after 10mins. AC Output Grid Type Single-phase Rated output power 10kW Rated Grid voltage 220Vac Grid voltage range 200~260Vac Rated Grid frequency 50Hz Work frequency range 49Hz~51Hz Rated output current 22.7A Thdi <5% (at rated power) Protection Functions AC output overvoltage/ undervoltage protection YES AC output over frequency /underfrequency protection YES AC short circuit protection YES Surge protection YES Anti-islanding protection YES Over-temperature protection YES Lightning protection YES General Parameters Display mode LED Display information dump load, grid state, wind generator state, faults Monitoring contents wind rotate speed, wind power, AC output voltage /current/power, and fault code Efficiency >93% Ambient temperature -20℃~+40℃ Humidity 0%~90%, no condensing Noise ≤65dB Cooling mode Forced air cooling Cover protection class IP54 Product dimension (W*H*D) 370×545×185mm Product net weight 19kg Dump load dimension(W*H*D) 390×730×190mm Dump load net weight 19kg Note: Part of parameters can be adjusted according to customer’s specific demand. Model WWGIT100 Wind Turbine Input Rated input power 10kW Max. input power 11kW Rated input voltage 380Vac Manual brake Keep pressing the button for 5s to unload completely, and then recover by pressing it for another 5s. Switch “ON” the brake switch Brake by over wind speed(optional) 18m/s (0~30m/s settable), it dumps load completely when reached the set wind speed, and recover automatically after working 10mins and wind speed is less than 15m/s. Brake by over rotational Speed(optional) 500r/min(factory default,0~1000r/min settable) Unload completely when reached the set rotational speed, and recover automatically after 10mins. AC Output Grid Type Three-phase Rated output power 10kW Rated Grid voltage 380Vac Grid voltage range 320~420Vac Rated Grid frequency 50Hz Work frequency range 49Hz~51Hz Rated output current 8A Thdi <5% (at rated power) Protection Functions AC output overvoltage/ undervoltage protection YES AC output over frequency /underfrequency protection YES AC short circuit protection YES Surge protection YES Anti-islanding protection YES Over-temperature protection YES Lightning protection YES General Parameters Display mode LED Display information dump load, grid state, wind generator state, faults Monitoring contents wind rotate speed, wind power, AC output voltage /current/power, and fault code Efficiency >93% Ambient temperature -20℃~+40℃ Humidity 0%~90%, no condensing Noise ≤65dB Cooling mode Forced air cooling Cover protection class IP54 Product dimension (W*H*D) 370×545×185mm Product net weight 19kg Dump load dimension(W*H*D) 390×730×190mm Dump load net weight 19kg Note: Part of parameters can be adjusted according to customer’s specific demand. Please connect those parts according to the order of ①②③④, and notice the following items. Connect two output lines of dump load to the unload terminals “R” “R” of the machine. Connect “L” “N” and earth wire of grid to the terminals “L” “N” and “” on the machine relatively. When wind turbine is still or running in a low speed, connects its output line to the “WIND INPUT” terminal on the machine. Connect communication device to the relative communication port if there is a communication device. Check all the connection to make sure they are connected rightly and tightly. Note: Please measure the voltage and frequency of the grid before connect the system to the grid. AC “L” “N” cannot be connected to the earth wire terminal, or the machine will be damaged permanently. The switch should be at “BRAKE” status while installation, and changed to “RUN” status when it works. Fault code Analysis Possible solutions 1 Grid is not normally connected. Grid voltage or frequency is abnormal Check the details from the monitoring software. 2 Inverting circuit soft over current protection Check the wiring connection on the AC side circuit after ensuring the machine is disconnected with any power supply. 3 Bus overvoltage protection Please connect Win Power 4 over temperature protection once the inverting module temperature recovers to normal, the machine will clear the fault itself. 5 IPM protection for the inverting side Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 6 Rectifying circuit soft over current protection Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 7 IPM protection for rectifying side Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power. 8 Wind voltage is higher than bus voltage fault protection point. Wait for 5mins, test after the fault is recovered automatically. If not, please contact Win Power.

8000W/10000W Step Up Step Down Transformer Voltage Converter 110V to/from 220V

Product name: power transformer Voltage regulation speed: <1 second (when the input voltage changes 10%) Product capacity: 10KVA overload protection: fuse or overload protection switch Frequency: 50Hz/60Hz Insulation class: Class B Warranty: 2 Years Working temperature: -5C~+40C Temperature rise protection: Yes Current: 36A MAX.