Schluter Ditra-Heat Cable 240V- 425.8 ft. (128.8 Sq. Ft)

Schluter Ditra-Heat Cable 240V- 425.8 ft. (128.8 Sq. Ft) DITRA-HEAT is the only system that provides floor warming and uncoupling in a single layer. The heating cables are easily snapped into place on top of the uncoupling mat with no clips or fasteners. The installer has complete flexibility on where the cables are placed so every installation is customized to suit the exact requirements of the owner. Because they are held securely within the DITRA-HEAT mat, there is no need to use self-leveling compounds to encapsulate the heating cables. Instead of waiting for a leveling compound to set, tile installation can begin immediately, resulting in a much faster installation. Features Twisted pair heating cables designed for integration with the DITRA-HEAT membrane Designed for interior floor warming applications Produces virtually zero electromagnetic fields Each heating cable includes 1 floor temperature sensor compatible with the Schluter®-DITRA-HEAT-E-RS thermostat and features an approximately 7 ft (2.1 m) long cold lead Heating Cable selection Tips Do not purchase a heating cable that is the same size as the area to be tiled; you will be left with too much heating cable! Very important: Never CUT or modify the heating cable in any way. This would change the cable resistance, will cause damage to the cable, and could cause cable overheating. Install the heating cable at a spacing of 3 studs (3-1/2″ – 9 cm).A narrower spacing may cause a fire or damage the floor covering. A wider spacing (e.g., 4 studs) may not provide sufficient power to warm the floor to the desired temperature. Minimum spacing from other heat sources (baseboard heaters, fireplaces, forced air heating ducts, etc.) is 8″ (200 mm) Minimum spacing from any plumbing drain is 6″ (150 mm). Minimum spacing from walls is 3″ (75 mm). Minimum spacing from fixed cabinets is 2″ (50 mm). NEVER install heating cable under vanities, bathtub platforms, kitchen cabinets and islands or any other fixtures. Excessive heat could build up in these confined spaces and may cause a fire. NEVER install the factory splice (i.e., black plastic junction between the cold lead and gray heating cable) in the wall. This will cause overheating, system failure, and could cause a fire. This splice must be installed entirely under the floor covering, as shown in the heating cable installation instructions. It is helpful to plan the location of a buffer zone, as it is not always possible to predict where the heating cable will end. The buffer zone is an area where heating is not essential, typically behind a toilet or adjacent to a door opening. This area allows for placement of excess heating cable. Heating cables may also be installed 6″ (150 mm) from the wall to create a buffer zone Consult a qualified electrician before ordering DITRA-HEAT heating cables to ensure you order the correct voltage for your installation. Coverage 425.8 ft. (128.8 Sq. Ft) Manufacturer Part # (MPN) DHEHK240129 Payments Shipping Returns

Titan N-120 tankless water heater

The Titan N-120 is the most popular of all Titan water heaters. Its microprocessor driven control board allows a fast temperature sampling rate and stable, efficient and reliable operation. With a Titan N-120 it’s easy to feel comfortable at home taking a shower, watching the dishes, or running any application that requires unlimited hot water. Saving money with a Titan N120 Tankless water heater is just done by the unit itself. This unit is able to adjust its power consumption in accordance with the hot water demand, allowing the unit to pay itself back in one year. This Titan water heater can save you hundreds of dollars each year when compared with a conventional water heater. While not in use, the Titan N120 consumes not energy at all. The N-120 can supply the hot water needs of a whole house or apartment in places where the incoming water is higher than 65 deg F. In colder places it can be used as a Point of Use water heater. Like any other Titan water heater, the Titan N-120 operates efficiently even on hard water. It comes with a 10 year warranty on all water carrying components and all other parts are guaranteed for one year. Installation is quick and easy, requiring no venting and its compact size allows installation almost anywhere. Technical Specifications/ Temperature Rise Chart MAX FLOW KW/HR VOLTS AMPS 1.0gpm 1.5gpm 2.0gpm 2.5gpm 3.0gpm 3.5gpm 4.0gpm 4.5gpm 5.0gpm 4.0 GPM 11.8 220 54 95 deg 64 deg 48 deg 38 deg 32 deg 28 deg 24 deg N/A N/A NOTE: One wire coming out of unit and it takes a 60 amp double pole breaker and a 6awg wire Product Measurements MODEL CURRENT POWER VOLTAGE Weight DIMENSIONS N-85 38Amps 8.5KW 220V 8 Pounds 7″ W x 10″ H x 3″ D N-100 49Amps 10.8KW 220V N-120 54Amps 11.8KW 220V Compliance………………….. Standards……………………. Tested ……………………… Dade Approval…………….. Dimensions………………….. Weight……………………….. Materials…………………….. Pipe Fitting………………….. Pressure Requirements….. Voltage………………………. Elements…………………….. Energy Efficiency…………. Activation…………………… Indicators…………………… Warranty……………………. Protection…………………… UL-#499 E212386 MET Laboratories # 97-0627-16 7″ W x 10″ H x 3″ D 8 Pounds Brass and Copper interior / Steel Casing. No plastics Used 1/2″ Standard Pipe 5 PSI-Min./150 PSI-Max 220 VAC Std. (208/277 Available) Dual Incoloy Nichrome Up to 99.5% 0.4 GPM-on / 0.3 GPM-off Red-on / Green-stand by 10 years on casing, 1 year on components Digital Temperature Control – Manual Resetable Thermostat