MPPT Solar Charge Controller+Bluetooth 12V/24V Auto Battery Regulator 40A 100VDC

1 x MPPT 40A. The system continuously optimizes power conversion efficiency for stable energy output. 🔗 【Parallel Expandable: Parallel Multiple Units for Higher Power Demands】Need more than 40A?. Simply parallel-connect multiple IPANDEE’s 40 Amp Solar Panel Regulator 12V/24V units to scale your system seamlessly—no extra hardware required.

EPEVER MPPT Solar Charge Controller 40A 12V 24V Auto for Solar Panel 520W 1040W

(2022 Upgraded Version) EPEVER MPPT Solar Charge Controller 40 Amp ,12V/24V DC auto work ,Max PV 100V ,Solar Panels Max input 520W charging for 12V battery or 1040W charging for 24V battery , Common Negative Grounded . Suitable for Lead-acid (Sealed / Gel(AGM) / Flooded); Lithium(LiFePO4 (4s/12V; 8s/24V), Li (NiCoMn)O2 (3s/12V; 6s/24V)) and User-defined .Technical Data:Model: Tracer4210ANRated charge and discharge current :40 AmpNominal system voltage:12V/24V DC auto workMax. PV input power: 520W charge for 12V battery system / 1040W charge for 24V battery systemMax. PV open circuit voltage:100V(at minimum operating environment temperature) 92V(at 25℃ environment temperature)Battery type :Lead-acid: Sealed (default)/ Gel/ AGM/ Flooded / User (9~17V@12V; 18~34V@ 24V) , Lithium: LiFePO4 (4s/12V; 8s/24V), Li (NiCoMn)O2 (3s/12V; 6s/24V), User (9~34V) and User-defined. (AGM battery setting same as GEL parameters, or more accurate parameters follow battery factory advice by User type )Grounding : Common negativeTracking efficiency : ≥99.5% , Max. conversion efficiency :98%Working environment temperature : -25℃~+50℃(100% input and output)Temperature: -20°C — +70°C/-4°F — 158°FLCD backlight time : 60S (Default)RS485 interface:5VDC/100mAController Terminals:#6 AWG(16mm2) ; Recommended Wire cable:#6 AWG(16mm2)Dimension:252*180*63mm ; weight :1.65 KGPackage List:1 X 40A MPPT Solar Charge Controller (Tracer4210AN )1 X Temperature sensor for controller(Model:RT-MF58R47K3.81A)1 X Manual (English)Note :Our warehous in Chicago, Illinois, our professional engineer local team supply solar system solutions and Tech-support services for you in time .2022 EPEVER Tracer-AN series mppt solar charge controller is new upgraded version , Better funcations and advanced technology .Added Features :Blacklight LCD Display ; More Safety Protection Functions ;Compatible with lead-acid and lithium-ion batteries too ;2022 Upgraded version support adjusting Lithium types by controller buttons directly . You could also contact vendor ( Goland Century ) services to get program firmware upgrade file , then you could set old version controller’s Lithium types by controller buttons too .Product Features:Based on common negative design and Advanced MPPT technology, with efficiency no less than 99.5%,Ultra-fast tracking speed and tracking efficiency ;With the adaptive three-stage charging mode based on digital control circuit, Tracer-AN series controllers can effectively prolong the life-cycle of battery and significantly improve the system performance. The load, utility or generator auto-control relays make it easy to compose the hybrid power system;All-around electronic protections, including overcharging, over discharging, PV reverse polarity protection, effectively ensure the safer and more reliable operation of the solar system for longer service time;The isolated RS485 interface with standard MODBUS communication protocol, easy for customer to monitor and set the parameters via mobile phone APP or PC software;This modular solar controller can be widely used for different applications, e.g.solar RV, Communication base stations, household systems, and field monitoring, etc.Protection function :•PV Over Current/power protection • PV Short Circuit protection • PV Reverse Polarity protection• Night Reverse Charging protection • Controller Overheating protection• Battery Reverse Polarity protection • Battery Over Voltage protection• Battery Over Discharge protection • Battery Overheating protection• Lithium Battery Low Temperature protection• Load Short Circuit protection • Load Overload protection•TVS High Voltage Transients protectionCONNECTION DIAGRAMBattery must be connected first ! Never connect soalr panel array to controller Without/Before connect battery.DO NOT connect any inverter/wind/Alternator or Charger into the charge controller directly ! You should connect with battery and add fuse .If there is a long distance between the PV array and controller or between the controller and battery, larger size wires should be used to reduce the voltage drop and improve performance. (Recommended wire size is only for reference.)How to program for Lithium Battery parameters ?Via Remote Meter (Accessories needed: MT50)Via Phone APP [ Android or IOS], (Accessories needed:WIFI Adapter or BLE Adapter )Via PC Software (Accessories needed RS485 cable :CC-USB-RS485-150U ) , Software download : EPEVER official website or read in manual .

EPEVER MPPT Solar Charge Controller 40A 12V 24V Auto for Solar Panel 520W 1040W

(2022 Upgraded Version) EPEVER MPPT Solar Charge Controller 40 Amp ,12V/24V DC auto work ,Max PV 100V ,Solar Panels Max input 520W charging for 12V battery or 1040W charging for 24V battery , Common Negative Grounded . Suitable for Lead-acid (Sealed / Gel(AGM) / Flooded); Lithium(LiFePO4 (4s/12V; 8s/24V), Li (NiCoMn)O2 (3s/12V; 6s/24V)) and User-defined .Technical Data:Model: Tracer4210ANRated charge and discharge current :40 AmpNominal system voltage:12V/24V DC auto workMax. PV input power: 520W charge for 12V battery system / 1040W charge for 24V battery systemMax. PV open circuit voltage:100V(at minimum operating environment temperature) 92V(at 25℃ environment temperature)Battery type :Lead-acid: Sealed (default)/ Gel/ AGM/ Flooded / User (9~17V@12V; 18~34V@ 24V) , Lithium: LiFePO4 (4s/12V; 8s/24V), Li (NiCoMn)O2 (3s/12V; 6s/24V), User (9~34V) and User-defined. (AGM battery setting same as GEL parameters, or more accurate parameters follow battery factory advice by User type )Grounding : Common negativeTracking efficiency : ≥99.5% , Max. conversion efficiency :98%Working environment temperature : -25℃~+50℃(100% input and output)Temperature: -20°C — +70°C/-4°F — 158°FLCD backlight time : 60S (Default)RS485 interface:5VDC/100mAController Terminals:#6 AWG(16mm2) ; Recommended Wire cable:#6 AWG(16mm2)Dimension:252*180*63mm ; weight :1.65 KGPackage List:1 X 40A MPPT Solar Charge Controller (Tracer4210AN )1 X Temperature sensor for controller(Model:RT-MF58R47K3.81A)1 X Manual (English)Note :Our warehous in Chicago, Illinois, our professional engineer local team supply solar system solutions and Tech-support services for you in time .2022 EPEVER Tracer-AN series mppt solar charge controller is new upgraded version , Better funcations and advanced technology .Added Features :Blacklight LCD Display ; More Safety Protection Functions ;Compatible with lead-acid and lithium-ion batteries too ;2022 Upgraded version support adjusting Lithium types by controller buttons directly . You could also contact vendor ( Goland Century ) services to get program firmware upgrade file , then you could set old version controller’s Lithium types by controller buttons too .Product Features:Based on common negative design and Advanced MPPT technology, with efficiency no less than 99.5%,Ultra-fast tracking speed and tracking efficiency ;With the adaptive three-stage charging mode based on digital control circuit, Tracer-AN series controllers can effectively prolong the life-cycle of battery and significantly improve the system performance. The load, utility or generator auto-control relays make it easy to compose the hybrid power system;All-around electronic protections, including overcharging, over discharging, PV reverse polarity protection, effectively ensure the safer and more reliable operation of the solar system for longer service time;The isolated RS485 interface with standard MODBUS communication protocol, easy for customer to monitor and set the parameters via mobile phone APP or PC software;This modular solar controller can be widely used for different applications, e.g.solar RV, Communication base stations, household systems, and field monitoring, etc.Protection function :•PV Over Current/power protection • PV Short Circuit protection • PV Reverse Polarity protection• Night Reverse Charging protection • Controller Overheating protection• Battery Reverse Polarity protection • Battery Over Voltage protection• Battery Over Discharge protection • Battery Overheating protection• Lithium Battery Low Temperature protection• Load Short Circuit protection • Load Overload protection•TVS High Voltage Transients protectionCONNECTION DIAGRAMBattery must be connected first ! Never connect soalr panel array to controller Without/Before connect battery.DO NOT connect any inverter/wind/Alternator or Charger into the charge controller directly ! You should connect with battery and add fuse .If there is a long distance between the PV array and controller or between the controller and battery, larger size wires should be used to reduce the voltage drop and improve performance. (Recommended wire size is only for reference.)How to program for Lithium Battery parameters ?Via Remote Meter (Accessories needed: MT50)Via Phone APP [ Android or IOS], (Accessories needed:WIFI Adapter or BLE Adapter )Via PC Software (Accessories needed RS485 cable :CC-USB-RS485-150U ) , Software download : EPEVER official website or read in manual .

EPever MPPT charge controller 40A 12/24V Solar Panel Regulator(Triron4210N)

EPEVER MPPT Solar Charge Controller 40Amp ,12V/24V DC auto work ,Max PV 100V , Max solar panels input 520W charging for 12V battery system / 1040W charging for 24V battery system, Common negative grounding . Suitable for Lead-acid battery and Lithium battery . Technical Data: Model: Triron4210N (UCS + DS2)Rated charge and discharge current :40 AmpNominal system voltage:12V/24V DC autoMax. PV input power: 520W charge for 12V battery system or 1040W @ 24V battery system Max. PV open circuit voltage:100V(at minimum operating environment temperature) ;92V(at 25℃ environment temperature)Grounding : Common negativeBattery input voltage range : 8~32VMPP voltage range:V(BAT+2V)~72VTracking efficiency : ≥99.5% , Max. conversion efficiency :98%Battery type : Lead-acid battery :Sealed / Gel(AGM) / Flooded/User (AGM battery parameters default same as GEL , or setting more accurate as factory advice parameters by USER type ) ; Lithium battery:LiFePO4 (4s/12V; 8s/24V) / Li (NiCoMn)O2 (3s/12V; 6s/24V) / User .Working environment temperature : -25℃~+55℃(100% input and output)Storage Temperature Range: -30°C — +70°C/-4°F — 158°FHumidity range :≤95%,(N.C)Enclosure:IP30Controller Terminals:#6 AWG(16mm2) Dimension:256.8*183*66.7mm ; Weight :1.85 KG Package List: 1 X 40A MPPT Solar Charge Controller Tracer4210AN 1 X Temperature sensor for controller(Model:RT-MF58R47K3.81A) 1 X Manual (English) Note : Our warehous in Chicago, Illinois, our professional engineer local team supply solar system solutions and tech-support services for you in time . EPEVER Triron-N series mppt solar charge controller is 2022 new upgraded version than Tacer-AN series , new designmodule, better funcations and advanced technology . Added Features than Tracer-AN series : Multiple LCD and LED display modules optional ,Master-slave interface module design,simultaneously view the controller and inverter operating data ;Dual USB design, supply DC power for electronic equipment ;Compatible with more battery types ( lead-acid and lithium-ion batteries too );More Safety Protection . Protection function : • PV over current protection • PV short circuit protection • PV reverse polarity protection • Night reverse charging protection • Lithium battery low temperature protection• Battery over heat protection • Controller overheating protection • Battery reverse polarity protection • Battery over discharge protection • Battery over voltage protection • Load short circuit protection • Load overload protection Product Features : Identify and load the drivers of various modules automatically.Support the hot swapping function without any damage for each module. Modular design for easy combination and replacement.Advanced MPPT control algorithm to minimize the maximum power point loss rate and loss timeHigh quality components, perfecting system performance, with maximum conversion efficiency of 98%. Ultra-fast tracking speed and great tracking efficiency ≥99.5% .Automatic limitation of the charging power and current , Wide MPP operating voltage range.Compatible with lead-acid and lithium-ion batteries; Multiple load work modes .LCD and indicators to display operating data and status of the system. Real-time energy statistics function, Overheating power reduction function.Provide 5VDC power through the dual USB output interface to charge electronic devices. Modular-Designed The main unit (Power Module) is a solar controller which can be integrated with different display and interface modules to meet a variety of functional requirements.TRIRION controller can be widely used in RV, telecommunication base station, household system, field monitoring, etc. Display Modular (DS2) Indicators: PV & battery & load working status; three color color lights, always on or flashing to inform you of the working status.Buttons: View or set the parametersLCD: PV display voltage/current /generated energy/Power Battery display voltage/current/temperature/capacityLoad:-Display voltage/ current/ power/ load working mode when the controller communicates with the PC or APP.-Display voltage/current/power power consumption when the controller communicates with the inverter(only epever inverter). Interface Module (UCS) USB interface module: Dual USB 5V 2.2A USB output for electronic equipment, NOTE: USB interface is output when the load is ON.COM port-RS485 interface: Controller as slave, Connect to PC or phone.PC software & mobile APP ( Andriod/IOS System) can remotely monitor the controller status through this port. NOTE: PC software & mobile APP need RS485 cable or wifi box to connect your device, RS485 cable and WIFI box doesn’t include package.It is optional. Heat Sink Back cooling plate, better heat dissipation effect, protect and extend the working life of the controller Step: Connect solar system in the order of 1.battery–> 2. load–> 3.PV array ; and disconnect solar system in the reverse order 3.> 2.> 1.Battery must be connected first ! Never connect soalr panel array to controller Without/Before connect battery.DO NOT connect any inverter/wind/Alternator or Charger into the charge controller directly ! You should connect with battery and add fuse .If there is a long distance between the PV array and the controller or between the controller and the battery, larger wires can be used to reduce the voltage drop and improve performance. (Recommended wire size is only for reference.)How to program for Lithium Battery?Via remote meter MT50 ;Via phone APP(Android or IOS) (Accessories needed:EPEVER-BLE-RJ45-D or EPEVER-WiFi-2.4G-RJ45-D ) ;Via PC software (Accessories needed RS485 cable :CC-USB-RS485-150U ) ,Software download website: EPever official website or read in manual .We have prepared Amazon listing video tutorials about how to use the controller and how to set parameters . More questions please feel free to ask vendor first . EPEVER-BLE-RJ45-D MPPT 20A MPPT 30A MPPT 40A MPPT 40A Rated Charge Current For EPEVER Controllers 20 Amp 30 Amp 40 Amp 40 Amp Max PV Voltage 100V 100V 100V 150V Max Array Solar Panel power 2600W/12V; 520W/24V 390W/12V; 780W/24V 520W/12V; 1040W/24V 520W/12V; 1040W/24V Battery Type Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Grounding Common Negative Common Negative Common Negative Common Negative Controller Terminal RS485 6AWG(16mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 ) Recommended Cable Size 10AWG(6mm 2 ) 8AWG(10mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 )

EPever MPPT charge controller 40A 12/24V Solar Panel Regulator(Triron4210N)

EPEVER MPPT Solar Charge Controller 40Amp ,12V/24V DC auto work ,Max PV 100V , Max solar panels input 520W charging for 12V battery system / 1040W charging for 24V battery system, Common negative grounding . Suitable for Lead-acid battery and Lithium battery . Technical Data: Model: Triron4210N (UCS + DS2)Rated charge and discharge current :40 AmpNominal system voltage:12V/24V DC autoMax. PV input power: 520W charge for 12V battery system or 1040W @ 24V battery system Max. PV open circuit voltage:100V(at minimum operating environment temperature) ;92V(at 25℃ environment temperature)Grounding : Common negativeBattery input voltage range : 8~32VMPP voltage range:V(BAT+2V)~72VTracking efficiency : ≥99.5% , Max. conversion efficiency :98%Battery type : Lead-acid battery :Sealed / Gel(AGM) / Flooded/User (AGM battery parameters default same as GEL , or setting more accurate as factory advice parameters by USER type ) ; Lithium battery:LiFePO4 (4s/12V; 8s/24V) / Li (NiCoMn)O2 (3s/12V; 6s/24V) / User .Working environment temperature : -25℃~+55℃(100% input and output)Storage Temperature Range: -30°C — +70°C/-4°F — 158°FHumidity range :≤95%,(N.C)Enclosure:IP30Controller Terminals:#6 AWG(16mm2) Dimension:256.8*183*66.7mm ; Weight :1.85 KG Package List: 1 X 40A MPPT Solar Charge Controller Tracer4210AN 1 X Temperature sensor for controller(Model:RT-MF58R47K3.81A) 1 X Manual (English) Note : Our warehous in Chicago, Illinois, our professional engineer local team supply solar system solutions and tech-support services for you in time . EPEVER Triron-N series mppt solar charge controller is 2022 new upgraded version than Tacer-AN series , new designmodule, better funcations and advanced technology . Added Features than Tracer-AN series : Multiple LCD and LED display modules optional ,Master-slave interface module design,simultaneously view the controller and inverter operating data ;Dual USB design, supply DC power for electronic equipment ;Compatible with more battery types ( lead-acid and lithium-ion batteries too );More Safety Protection . Protection function : • PV over current protection • PV short circuit protection • PV reverse polarity protection • Night reverse charging protection • Lithium battery low temperature protection• Battery over heat protection • Controller overheating protection • Battery reverse polarity protection • Battery over discharge protection • Battery over voltage protection • Load short circuit protection • Load overload protection Product Features : Identify and load the drivers of various modules automatically.Support the hot swapping function without any damage for each module. Modular design for easy combination and replacement.Advanced MPPT control algorithm to minimize the maximum power point loss rate and loss timeHigh quality components, perfecting system performance, with maximum conversion efficiency of 98%. Ultra-fast tracking speed and great tracking efficiency ≥99.5% .Automatic limitation of the charging power and current , Wide MPP operating voltage range.Compatible with lead-acid and lithium-ion batteries; Multiple load work modes .LCD and indicators to display operating data and status of the system. Real-time energy statistics function, Overheating power reduction function.Provide 5VDC power through the dual USB output interface to charge electronic devices. Modular-Designed The main unit (Power Module) is a solar controller which can be integrated with different display and interface modules to meet a variety of functional requirements.TRIRION controller can be widely used in RV, telecommunication base station, household system, field monitoring, etc. Display Modular (DS2) Indicators: PV & battery & load working status; three color color lights, always on or flashing to inform you of the working status.Buttons: View or set the parametersLCD: PV display voltage/current /generated energy/Power Battery display voltage/current/temperature/capacityLoad:-Display voltage/ current/ power/ load working mode when the controller communicates with the PC or APP.-Display voltage/current/power power consumption when the controller communicates with the inverter(only epever inverter). Interface Module (UCS) USB interface module: Dual USB 5V 2.2A USB output for electronic equipment, NOTE: USB interface is output when the load is ON.COM port-RS485 interface: Controller as slave, Connect to PC or phone.PC software & mobile APP ( Andriod/IOS System) can remotely monitor the controller status through this port. NOTE: PC software & mobile APP need RS485 cable or wifi box to connect your device, RS485 cable and WIFI box doesn’t include package.It is optional. Heat Sink Back cooling plate, better heat dissipation effect, protect and extend the working life of the controller Step: Connect solar system in the order of 1.battery–> 2. load–> 3.PV array ; and disconnect solar system in the reverse order 3.> 2.> 1.Battery must be connected first ! Never connect soalr panel array to controller Without/Before connect battery.DO NOT connect any inverter/wind/Alternator or Charger into the charge controller directly ! You should connect with battery and add fuse .If there is a long distance between the PV array and the controller or between the controller and the battery, larger wires can be used to reduce the voltage drop and improve performance. (Recommended wire size is only for reference.)How to program for Lithium Battery?Via remote meter MT50 ;Via phone APP(Android or IOS) (Accessories needed:EPEVER-BLE-RJ45-D or EPEVER-WiFi-2.4G-RJ45-D ) ;Via PC software (Accessories needed RS485 cable :CC-USB-RS485-150U ) ,Software download website: EPever official website or read in manual .We have prepared Amazon listing video tutorials about how to use the controller and how to set parameters . More questions please feel free to ask vendor first . EPEVER-BLE-RJ45-D MPPT 20A MPPT 30A MPPT 40A MPPT 40A Rated Charge Current For EPEVER Controllers 20 Amp 30 Amp 40 Amp 40 Amp Max PV Voltage 100V 100V 100V 150V Max Array Solar Panel power 2600W/12V; 520W/24V 390W/12V; 780W/24V 520W/12V; 1040W/24V 520W/12V; 1040W/24V Battery Type Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Sealed / Gel(AGM) / Flooded;LiFePO4 / Li-NiCoMn / User Grounding Common Negative Common Negative Common Negative Common Negative Controller Terminal RS485 6AWG(16mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 ) Recommended Cable Size 10AWG(6mm 2 ) 8AWG(10mm 2 ) 6AWG(16mm 2 ) 6AWG(16mm 2 )