DAYTON 3C510 Fan Shutter,24 In,White Painted Aluminum 3C510
26 In.H 32 In.W Aluminum Ceiling Fan Damper, Frame Material Aluminum, Number of Panels 1, Maximum Air Velocity 1500 fpm, Overall Height 26 in, Rough Opening Shape Rectangular, Fits Fan Diameter 24 in, Free Area 3.3 sq ft, Overall Width 32 in, Frame Material Thickness 0.1 in, Frame Depth 1 3/8 in, Rough Opening Length 24 in, Maximum Pressure 1 in wc, Rough Opening Width 30 in, Blade Material Aluminum, Closure Type Gravity, Flange Width 1 5/8 in The DAYTON(R) ceiling truss shutter is recommended for horizontal-mount exhaust in residential ceilings for whole house fans. Truss shutter installs without framing or cutting the ceiling joist. Tie rods at each end side of shutter assure uniform opening when fan is operating. White extruded aluminum frame with 1-1/2″ flange and 3/16″-dia. mounting h.
DAYTON 4YN20 Fan Shutter,16 In,White Painted Aluminum 4YN20
19 In.H-W 6 In.L Aluminum Gable Shutter Damper, For Nominal Duct Diameter Not Applicable, Frame Material Aluminum, Number of Panels 1, Maximum Air Velocity 2500 fpm, Overall Height 19 in, Rough Opening Diameter 16 1/2 in, Rough Opening Shape Square, Fits Fan Diameter 16 in, For Duct Shape Not Applicable, Free Area 1.4 sq ft, Overall Width 19 in, Frame Material Thickness 0.8 in, Overall Length 6 in, Connection Type Not Applicable, Frame Depth 1 1/2 in, Rough Opening Length 17 in Designed for use with gable-mounted power attic ventilators. The shutters feature aluminum construction and flush mount for easy installation. They also open automatically when ventilator is running. Weather stripping on blades for positive seal when not in use. Tie rods on blades help to ensure uniform opening whil.
Dayton 60L500 Replacement Gearbox – New – Free Shipping
Gearbox For Use With 13F046; 13F047; 1VCF2; 1VCF3; 1VCF4; 3PEH1.
Dayton Plastic 12″L 5″W 6″H Fan Grease Trap 48C174 Dayton 48C174 190735320174
Grease Collector Box, Fits Square Base Size Not Applicable, Compatible Grainger Part Number All Dayton Centrifugal Upblast Exhaust Ventilators, Material Plastic, Includes (2) 1/4 in x 3/4 in Flat Washer, (2) 1/4 in x 3/4 in Sheet Metal Screw, Mounting Hardware, For Fan Type Upblast Fans, For Fan Mounting Type Roof Mount, Container Capacity 1 gal, Standards AMCA, NFPA 96, UL 762, Compatible Manufacturer Model Number C-Series Product, For Use With Dayton Upblast Roof Ventilators Dayton.
DAYTON 48C174 Plastic 12″L 5″W 6″H Fan Grease Trap 48C174
Grease Collector Box, Fits Square Base Size Not Applicable, Compatible Grainger Part Number All Dayton Centrifugal Upblast Exhaust Ventilators, Material Plastic, Includes (2) 1/4 in x 3/4 in Flat Washer, (2) 1/4 in x 3/4 in Sheet Metal Screw, Mounting Hardware, For Fan Type Upblast Fans, For Fan Mounting Type Roof Mount, Container Capacity 1 gal, Standards AMCA, NFPA 96, UL 762, Compatible Manufacturer Model Number C-Series Product, For Use With Dayton Upblast Roof Ventilators Dayton Protect rooftop surfaces and roof-mounted centrifugal upblast ventilators from heavy grease residue with this Dayton(R) grease trap. It fastens directly to a ventilated roof curb and collects heavy grease residue while protecting the roof surface. A connection from ventilator drain to the grease box is include.
Dayton 48C174 Grease Trap Small
Light Industrial. & Recepticles. Electrical Outlets. and Enclosures. Electrical Boxes. General Purpose. & Industrial.
DAYTON Electric Wall/Ceiling Heat,11 A, 12.5 A 804T10
Electric Wall & Ceiling Unit Heater, Overall Height 16 in, Overall Width 14 in, Overall Depth 8 1/2 in, Air Flow 350 cfm, Air Temp. Rise 27 Degrees F, Voltage 208/240 V AC, 1 Phase, Wattage Output 2.2 kW, 3 kW, Heating Method Fan Forced, Heating Capacity 10,200 BtuH, 7,500 BtuH, Mounting Location Ceiling, Wall, Horizontal Air Throw 12 ft, Frequency 60 Hz, Amperage 11 A, 12.5 A, Control Type Mechanical Selector Dial, Contactor Coil Voltage 208/240V AC, Housing Color Beige.
DAYTON 4HU84 1 HP,Sewage Ejector Pump,460VAC
NO ORIGINAL BOX
DAYTON 4HU84 1 HP,Sewage Ejector Pump,460VAC 4HU84
Sewage Ejector Pump, HP 1, Rated Voltage 460V AC, Phase – Pumps 3, Amps 3.70 A, Motor Type Hermetically Sealed/Oil Filled, Body Material Cast Iron, Impeller Material Cast Iron, Shaft Seal Material – Pumps Silicone Carbide, Switch Actuation No Switch Included, Switch Electrical Connection No Switch Included, Flow Rate @ 20 Ft. of Head 135 gpm, Flow Rate @ 40 Ft. of Head 70 gpm, Max. Diameter Solids 2 in, Body Dia. 12 5/8 in, Overall Height 19 1/16 in, Cord Length 20 ft, Discharge 2 in NPT These general purpose three-phase 200 to 480V sewage ejector pumps use a higher voltage that allows for larger motors that require less current than lower-voltage motors. They also use three-phase power that’s more efficient than one-phase power. Pumps remove sewage containing solids from drains where a gr.
DAYTON 3BB90 1 HP,Sewage Ejector Pump,240VAC 3BB90
Sewage Ejector Pump, HP 1, Rated Voltage 240V AC, Phase – Pumps 1, Amps 10.70 A, Body Material Cast Iron, Impeller Material Cast Iron, Shaft Seal Material – Pumps Silicone Carbide, Switch Actuation Tether Float, Switch Electrical Connection Piggyback, Flow Rate @ 20 Ft. of Head 135 gpm, Flow Rate @ 40 Ft. of Head 70 gpm, Max. Diameter Solids 2 in, Body Dia. 12 5/8 in, Overall Height 19 1/16 in, Cord Length 20 ft, Discharge 2 in NPT, Max. Liquid Temp. 104 Degrees F, Max. Head 52 ft, RPM 3,450 RPM These general purpose single-phase 200 to 240V sewage ejector pumps use a higher voltage that allows for larger motors that require less current than lower-voltage motors. They remove sewage containing solids from drains where a gravity system won’t work, such as in septic systems that are below th.