Stainless Steel Copper Brazed Heat Exchanger Mounting Studs Water Boiler Radiant

Plate Heat Exchangers Copper Brazed Stainless Steel Plates by Duda Energy Free Shipping Hawaii, Alaska, US Protectorates & PO Boxes: Additional postage may be due for models other than the B3-12A, B3-23A & B3-14DW Our plate heat exchangers come with mounting studs welded on the back. We use M5-0.8 studs for B3-12A models and M8-1.25 studs for all other sizes. Recommended for: Boilers, wood stoves, solar water heating, refrigeration, SVO conversions, Heat Pumps, Central Air Conditioning, Industrial Water Cooling, Oil Coolers and any application where heat transfer between two fluids is required. Need help choosing a unit? Generally speaking, the longer the heat exchanger is, the more efficient it will be. Adding more plates reduces pressure loss and adds some extra heat transfer. More width on a unit also reduces pressure loss and adds some heat transfer. Since plate heat exchanger utilize convection, it is better to add length than plates or width for heat transfer when the flow rates are low. (adding more plates or width reduces fluid velocity and thus, less convection) For a specific sizing to your requirements, please see our heat exchanger sizing form. Duda Diesel Plate Heat Exchangers Specifications Sheet by Model Model B3-12A B3-14DW B3-23A B3-36A B3-32A B3-32DW B3-52A B3-95A B3-115A Length 7.5″ 7.8″ 12.4″ 18.3″ 11.256″ 20.7″ 24.3″ 21.1″ Width 2.9″ 3.46″ 2.9″ 2.9″ 4.56″ 4.4″ 7.5″ 10″ Height 2.24mm/plate + 7mm 0.088″/plate + 0.275″ 2.4mm/plate+ 7mm 0.095″/plate + 0.275″ Max Number of Plates 60 120 200 300 Max Connection Size 3/4″ Thread 7/8″ Welded 1″ Threaded 1-1/8″ Welded 2″ Threaded 2-1/8″ Welded 3″ Threaded 3-1/8″ Welded Heat Transfer Area/Plate 0.012 m²/plate 0.14 ft²/plate 0.014 m²/plate 0.14 ft²/plate 0.023 m²/plate 0.247 ft²/plate 0.036 m²/plate 0.327 ft²/plate 0.032 m²/plate 0.327 ft²/plate 0.052 m²/plate 0.560 ft²/plate 0.095 m²/plate 0.9728 ft²/plate 0.115 m²/plate 1.24 ft²/plate Thickness of plates 0.3 mm (.0118″) 0.4 mm (.0157″) Max Flow Rate 66.6 L/min 17.6 gpm 200 Lpm 53 gpm 583 L/min 154 gpm 1000 L/min 264 gpm Channel Capacities 0.018 L/channel 0.004756 gal/channel 0.022 L/channel 0.006 gal/channel 0.04 L/channel 0.0105 gal/channel 0.05 L/channel 0.0132 gal/channel 0.094 L/channel 0.025 gal/channel 0.25 L/channel 0.066 gal/channel 0.29 L/channel 0.076 gal/channel Design pressure 1.0 Mpa (145 psi) 3.0 Mpa (435 psi) Test Pressure 2.0 Mpa (290 psi) 4.5 Mpa (650 psi) Design Temperature -195°C to +220°C (-319°F to 430°F) Refrigeration Capacity 1-5 KW 3400-17,000 BTU/hour 1-6 KW 3400-21,000 BTU/hour 3-10 KW 10,000-34,000 BTU/hour 4-15 KW 17,000-61,200 BTU/hour 5-20 KW 17,000-85,000 BTU/hour 10-70 KW 34,000-238,000 BTU/hour 30-200 KW 102,000-680,000 BTU/hour Flow direction F1-F3 and F2-F4

2-Piece Stainless Steel Ball Valves WOG1000

2-Piece Stainless Steel Ball Valveswith PTFE Seals & Seatsby Duda Energy Duda Energy’s Stainless Steel Ball Valves with PTFE (Teflon) Seats & Seals offer excellent corrosion resistance for most applications. Stainless Steel & PTFE work well in applications including but not limited to water, oil, gas/air, light alkali’s and acids, biodiesel, fuels and alcohols. These ball valves are fitted with tight seals to ensure no leakage and a long lasting seal after many years of frequent usage. Descriptions of Different Duda Energy Ball Valve Types Valve Type Description 2-Piece Ball Valve Full port ball valve which can unthread on one side for service. 3-Piece Ball Valve Full port ball valve held together by bolts which can be taken apart for service or removed from the piping without removal of the piping itself 3-Way Ball Valve (L-Type) Used to direct flow of a fluid from one set of piping to another alternate set 3-Way Ball Valve (T-Type) Like the L-Type, may be used to direct fluid flow to one set of of piping or another. It can also disconnect the main pipe and connect the two alternate pipes together, or connect all 3 together with no blockage. 2-Piece Ball Valve Material Identifications Part Identification Material 1. Nut 304 Stainless Steel / CF8 2. Spring Washer 3. Stem 4. Handle 5. Gland Nut 6. Packing PTFE (Teflon) 7. Thrust Washer 8. Bonnet 304 Stainless Steel / CF8 9. Seal Ring PTFE (Teflon) 10. Seat 11. Ball 304 Stainless Steel / CF8 12. Body General Specifications for SUS304 Ball Valves Fluid Media Water, Oil, Biodiesel, Air & Other Fluids Max Working Temperature -29°C to 210°C (-20°F to 410°F) Nominal Working Pressure 1000 Psi Shell Test Pressure 10.4 Mpa (1500 psi) Tightness Test Pressure 7.6 Mpa (1100 psi) Gas Tightness Test Pressure 0.4~0.7 Mpa (58~100 psi) Port Types: Female NPT x Female NPT

DFD High Pressure Solenoid Valve DIN Wiring Terminal Electric Pneumatic Chemical

Heavy Duty DFD High Pressure Solenoid Valves Duda Energy Heavy Duty Solenoid Valves are made with thick valve bodies and extra copper containing coils for longer lasting life and higher stress taking applications. Need an Electronic Timer for Automated Control of your Solenoid Valve? Check out the Duda Energy Electronic Switch Timers Here. The DFD series valve is a two way solenoid valve which has 2 ports in which fluid flows from/to. These valves open/close with assistance of applied pressure from the working fluid. The valves require pressure to open/close because there is a high powered spring, which enables higher maximum operating pressures than zero pressure solenoid valves. Available in a body/seal material of brass/NBR or stainless steel/viton. Brass/NBR valves are suitable for water, hot water, gas, air, and non-corrosive oils. Stainless Steel/Viton valves are suitable for hot water, weak acids, weak alkali, chemical salt, oils and hydrocarbon. Flow of the Valve These valves only allow flow in one direction. Pressure from the working fluid is required to open/close the valve when activated. If flowing in the wrong direction, the valve may not be able to open/close. Electrical Connection The electric coil uses a DIM connector. This connect contains wiring terminals for easy connection and a simple connect/disconnect: Simply unscrew the DIM connector and unplug the valve for service (no need to disconnect the wires from the terminals). The coils are not polarized, which mean that positive/negative does not matter when wiring them. We highly recommend using the ground terminal in the DIM connector to avoid electric shock when touching the valve. Coil Use The coils are designed to withstand heat build-up from continuous use as long as they are exposed to ambient and not insulated in order to dissipate heat. Although they can be used continuously without shutoff, it will reduce the life of the coil to operate them constantly. DC valves will experience more rapid heating than AC valves due to the higher amperage required to operate them. Working Fluid The working fluid can be a variety of substances. The fluid must be clean of debris for proper operation of the solenoid valve. If any debris gets into the valve body, it can clog the diaphragm from a complete seal, thus preventing a a successful closure of the valve. In the event of clogging, these valves are easy to clean. Simply remove the 4 bolts holding the body together to access the diaphragm for cleaning. Model Numbers Model numbers are listed below for brass, normally closed valves. If stainless steel, a JV is to be added after the mm size. If normally open, a K is to be added after mm size and between the JV on stainless steel. DFD Pressure Solenoid Valve Parameters Model DFD-15 DFD-20 DFD-25 DFD-32 DFD-40 DFD-50 Thread Connection (NPT) 1/2″ 3/4″ 1″ 1-¼ 1½” 2″ Orifice Size (mm) 16 20 25 32 40 50 Motion Pattern Se mi-Direct Lift Cv Value 3.73 7 11.1 14 24.5 35 L (mm) 80 87 107 129 145 177 H (mm) 105 114 122 131 142 155 H1 (mm) 93.5 98 100 107 116 122.5 Fluid Working Temperature Brass/NBR: -5°C – 80°C (29°F – 176°F), Stainless Steel /Viton: -10°C – 130°C (26°F – 266°F) Working Pressure Normally Closed Normally Open 0.3-12 Bar (4.5 – 170 psi) 0.3 – 8 Bar (4.5 – 113 psi) Maximum Power Consumption 12v-24v: 14 Watts 110v-220v: 26 Watts Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

2-Way Brass Solenoid Valve NBR Seals DIN Gas Air Water Oil Electric Pneumatic

Heavy Duty 2-Way Solenoid Valves Brass Body with Nitrile Rubber Seals By Duda Energy For use with Water, Air, Gas and Non-Corrosive Oils Duda Energy Heavy Duty Solenoid Valves are made with thick valve bodies and extra copper containing coils for longer lasting life and higher stress taking applications. Available in: Port Sizes: 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″, 2″ Body Types/Diaphragm: Brass/NBR or Stainless Steel/Viton Voltages: 12v DC, 24v DC, 24v AC, 110v AC, 220v AC Need an Electronic Timer for Automated Control of your Solenoid Valve? Check out the Duda Energy Electronic Switch Timers Here. Free Shipping When the free shipping method is selected, most orders will ship by USPS Priority Mail. If multiple quantities are ordered for a total over $250, we may opt to send the shipment by Fedex Ground to ensure that the package is delivered with a signature so that there is no risk of a stolen package. Description A two way solenoid valve means that there are 2 ports in which fluid flows from/to. The Direct Acting valves will stop flow in either direction, but are still only designed to allow full flow in a single direction. Semi-Direct acting valves require assitance from fluid flow to open. These 2W valves open/close with a 0 psi working pressure. However, while they do not require pressure from the working fluid to remaing open or remain closed, the semi-direct lift valves do require some assistance from the fluid for the initial opening/closing. Some gravity flow applications may have trouble overcoming the static friction of the seals within the valve while initially opening or closing. General purpose 2-way direct acting and semi-direct lift acting valves. Common applications include water, oil (below 20cst), air, gas, freon, *vacuum, weak acids & weak alkali. Check chemical compatibility charts for the valve body and seals of the valves to see if they are compatible in the case of using a weak acid/base. *Only Solenoid valves of 1″ ports and smaller are able to operate with full vacuum. Available in a body/seal material of brass/NBR or stainless steel/viton. Brass/NBR valves are suitable for water, hot water, gas, air, non-corrosive oils and freon. Stainless Steel/Viton valves are suitable for hot water, weak acids, weak alkali, chemical salt, oils and hydrocarbons such as *Diesel Fuel. *Diesel fuel is compatible with Brass/NBR, however, it is known to slightly shrink NBR and with any small shrinkage of the material in the diaphragm, it can cause a solenoid vale to cease in operation. For this reason, we only warranty the stainless steel/viton valves for diesel fuel and similar applications. Flow of the Valve The Semi-Direct Lift valves will partially open or close from activation, and require fluid assitance to prop open or closed. They can only stop flow in one direction, which is indicated by the arrow on the body of the valve. If pressure is applied in the opposite direction, the valve will be opened and allow a slow trickle of fluid in the opposite direction. These valves should only be used for stopping flow in one direction. If preventing of backflow is required, a check valve should be placed in the line after the solenoid valve. Direct acting valves switch on their own with no fluid assitance and can block fluid flow in both directions. Electrical Connection The electric coil uses a DIN connector. This connect contains wiring terminals for easy connection and a simple connect/disconnect: Simply unscrew the DIN connector and unplug the valve for service (no need to disconnect the wires from the terminals). The coils are not polarized, which mean that positive/negative does not matter when wiring them. We highly recommend using the ground terminal in the DIN connector to avoid electric shock when touching the valve. Coil Use The coils are designed to withstand heat build-up from continuous use as long as they are exposed to ambient and not insulated in order to dissipate heat. Although they can be used continuously without shutoff, it will reduce the life of the coil to operate them constantly. DC valves will experience more rapid heating than AC valves due to the higher amperage required to operate them. The rated maximum power consumption often only occurs when the valve operates near the maximum pressure. When no pressure is applied, the valve’s power consumption is about 1/3 of the maximum power consumption. Limitations of the Larger Valves For the larger valves (1-1/4″ and up), when operating near the maximum pressure, it can take a little longer for them to close than the smaller valves. Because of this, some applications with larger valves may also experience a “fluttering” sound as the valve tries to close against the high pressure. Valves larger than 1″ cannot hold a full vacuum. It is recommended to use the smaller valves for vacuum applications, especially if near full vacuum needs to be achieved. Working Fluid The working fluid can be a variety of substances. The fluid must be clean of debris for proper operation of the solenoid valve. If any debris gets into the valve body, it can clog the diaphragm from a complete seal, thus preventing a a successful closure of the valve. In the event of clogging, these valves are easy to clean. Simply remove the 4 bolts holding the body together to access the diaphragm for cleaning. Model Numbers Model numbers are listed below for brass, normally closed valves. If stainless steel, a J is to be added after the W. If normally open, a K is to be added before the N. Solenoid Valve Parameters Model 2W-040-08N 2W-160-10N 2W-160-15N 2W-200-20N 2W-250-25N 2W-320-32N 2W-400-40N 2W-500-50N Thread Connection (NPT) 1/4″ 3/8″ 1/2″ 3/4″ 1″ 1-¼ 1½” 2″ Orifice Size (mm) 4 16 16 20 25 35 40 50 Motion Pattern Direct Acting Semi-Direct Lift Cv Value 0.6 4.8 7.6 12 24 29 48 L 40.5 52.5 69 73 99 119 123 168 H 75 90 117 123.5 134.5 170 172 209 H1 66 76 101 107 113 143 144 172 Fluid Working Temperature Brass/NBR: -5°C – 80°C (29°F – 176°F), Stainless Steel /Viton: -10°C – 130°C (14°F – 266°F) Working Pressure Voltage Normally Closed Normally Open 110v AC or 220v AC 0-10 Bar (0-145 psi) 0-5 Bar (0-71 psi) 12v DC or 24v DC 0-5 Bar (0-71 psi) 0-5 Bar (0-71 psi) Maximum Power Consumption Normally Closed Valves

Duda Energy Female NPT Hose Barb Female NPT Hose Barb Adapter

Introducing our latest line of premium-grade stainless steel fittings crafted from high-quality 304 Stainless Steel, renowned for its exceptional corrosion resistance against a diverse array of chemicals. Engineered to meet the stringent demands of various applications, these fittings are the epitome of durability and reliability. Perfect for a wide range of uses, including water plumbing, corrosive chemical systems, alcohol systems, oil systems, and more, our stainless steel fittings are the ultimate choice for industries seeking top-tier performance. To ensure precise compatibility for your specific application, we recommend consulting reputable chemical compatibility references such as the Cole Parmer Chemical Compatibility Database. Designed to withstand extreme conditions, these fittings boast an impressive working fluid temperature range of -196°C to +220°C (-321°F to 428°F), providing unparalleled versatility across diverse environments. Whether you’re dealing with sub-zero temperatures or high-temperature applications, our fittings are up to the challenge. Furthermore, these fittings are engineered for use in systems with pressures of 150 psi or less, offering a reliable and robust solution for a wide range of fluid handling systems. Elevate your operations with the assurance of quality and longevity that our 304 Stainless Steel fittings bring to the table. Features : Pipe Fitting Type : Female Hose Barb AdapterCorrosion Resistance: 304 Stainless Steel exhibits excellent corrosion resistance, making it suitable for various environments, including those with high humidity, chemicals, and salt exposure.Temperature Resistance: Stainless Steel can withstand a wide range of temperatures, making it suitable for applications where thermal fluctuations occur, from cryogenic temperatures to elevated heat.Durable Construction: The fittings are crafted from high-quality stainless steel, ensuring durability and longevity, even in demanding industrial settings.Industry Standards: Opt for fittings compliant with industry standards to guarantee seamless integration into existing systems.

Male Garden x Female NPT Garden Hose Quick-Disconnect Garden Hose Fittings

Introducing our latest line of premium-grade stainless steel fittings crafted from high-quality 304 Stainless Steel, renowned for its exceptional corrosion resistance against a diverse array of chemicals. Engineered to meet the stringent demands of various applications, these fittings are the epitome of durability and reliability. Perfect for a wide range of uses, including water plumbing, corrosive chemical systems, alcohol systems, oil systems, and more, our stainless steel fittings are the ultimate choice for industries seeking top-tier performance. To ensure precise compatibility for your specific application, we recommend consulting reputable chemical compatibility references such as the Cole Parmer Chemical Compatibility Database. Designed to withstand extreme conditions, these fittings boast an impressive working fluid temperature range of -196°C to +220°C (-321°F to 428°F), providing unparalleled versatility across diverse environments. Whether you’re dealing with sub-zero temperatures or high-temperature applications, our fittings are up to the challenge. Furthermore, these fittings are engineered for use in systems with pressures of 150 psi or less, offering a reliable and robust solution for a wide range of fluid handling systems. Elevate your operations with the assurance of quality and longevity that our 304 Stainless Steel fittings bring to the table. Features : Pipe Fitting Type : Quick-Disconnect Garden Hose FittingsCorrosion Resistance: 304 Stainless Steel exhibits excellent corrosion resistance, making it suitable for various environments, including those with high humidity, chemicals, and salt exposure.Temperature Resistance: Stainless Steel can withstand a wide range of temperatures, making it suitable for applications where thermal fluctuations occur, from cryogenic temperatures to elevated heat.Durable Construction: The fittings are crafted from high-quality stainless steel, ensuring durability and longevity, even in demanding industrial settings.Industry Standards: Opt for fittings compliant with industry standards to guarantee seamless integration into existing systems.

2-Way Stainless Steel Solenoid Valve Viton Seals Acid Alkali Oil Fuel Pneumatic

Heavy Duty 2-Way Solenoid Valves Stainless Steel with Viton Seals By Duda Energy For use with Water, Gas, Air, Oil, Light Alkaline and Light Acidic Fluids Duda Energy Heavy Duty Solenoid Valves are made with thick valve bodies and extra copper containing coils for longer lasting life and higher stress taking applications. Available in: Port Sizes: 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″, 2″ Body Types/Diaphragm: Brass/NBR or Stainless Steel/Viton Voltages: 12v DC, 24v DC, 24v AC, 110v AC, 220v AC Need an Electronic Timer for Automated Control of your Solenoid Valve? Check out the Duda Energy Electronic Switch Timers Here. Free Shipping When the free shipping method is selected, most orders will ship by USPS Priority Mail. If multiple quantities are ordered for a total over $250, we may opt to send the shipment by Fedex Ground to ensure that the package is delivered with a signature so that there is no risk of a stolen package. Description A two way solenoid valve means that there are 2 ports in which fluid flows from/to. The Direct Acting valves will stop flow in either direction, but are still only designed to allow full flow in a single direction. Semi-Direct acting valves require assitance from fluid flow to open. These 2W valves open/close with a 0 psi working pressure. However, while they do not require pressure from the working fluid to remaing open or remain closed, the semi-direct lift valves do require some assistance from the fluid for the initial opening/closing. Some gravity flow applications may have trouble overcoming the static friction of the seals within the valve while initially opening or closing. General purpose 2-way direct acting and semi-direct lift acting valves. Common applications include water, oil (below 20cst), air, gas, freon, *vacuum, weak acids & weak alkali. Check chemical compatibility charts for the valve body and seals of the valves to see if they are compatible in the case of using a weak acid/base. *Only Solenoid valves of 1″ ports and smaller are able to operate with full vacuum. Available in a body/seal material of brass/NBR or stainless steel/viton. Brass/NBR valves are suitable for water, hot water, gas, air, non-corrosive oils and freon. Stainless Steel/Viton valves are suitable for hot water, weak acids, weak alkali, chemical salt, oils and hydrocarbons such as *Diesel Fuel. *Diesel fuel is compatible with Brass/NBR, however, it is known to slightly shrink NBR and with any small shrinkage of the material in the diaphragm, it can cause a solenoid vale to cease in operation. For this reason, we only warranty the stainless steel/viton valves for diesel fuel and similar applications. Flow of the Valve The Semi-Direct Lift valves will partially open or close from activation, and require fluid assitance to prop open or closed. They can only stop flow in one direction, which is indicated by the arrow on the body of the valve. If pressure is applied in the opposite direction, the valve will be opened and allow a slow trickle of fluid in the opposite direction. These valves should only be used for stopping flow in one direction. If preventing of backflow is required, a check valve should be placed in the line after the solenoid valve. Direct acting valves switch on their own with no fluid assitance and can block fluid flow in both directions. Electrical Connection The electric coil uses a DIN connector. This connect contains wiring terminals for easy connection and a simple connect/disconnect: Simply unscrew the DIN connector and unplug the valve for service (no need to disconnect the wires from the terminals). The coils are not polarized, which mean that positive/negative does not matter when wiring them. We highly recommend using the ground terminal in the DIN connector to avoid electric shock when touching the valve. Coil Use The coils are designed to withstand heat build-up from continuous use as long as they are exposed to ambient and not insulated in order to dissipate heat. Although they can be used continuously without shutoff, it will reduce the life of the coil to operate them constantly. DC valves will experience more rapid heating than AC valves due to the higher amperage required to operate them. The rated maximum power consumption often only occurs when the valve operates near the maximum pressure. When no pressure is applied, the valve’s power consumption is about 1/3 of the maximum power consumption. Limitations of the Larger Valves For the larger valves (1-1/4″ and up), when operating near the maximum pressure, it can take a little longer for them to close than the smaller valves. Because of this, some applications with larger valves may also experience a “fluttering” sound as the valve tries to close against the high pressure. Valves larger than 1″ cannot hold a full vacuum. It is recommended to use the smaller valves for vacuum applications, especially if near full vacuum needs to be achieved. Working Fluid The working fluid can be a variety of substances. The fluid must be clean of debris for proper operation of the solenoid valve. If any debris gets into the valve body, it can clog the diaphragm from a complete seal, thus preventing a a successful closure of the valve. In the event of clogging, these valves are easy to clean. Simply remove the 4 bolts holding the body together to access the diaphragm for cleaning. Model Numbers Model numbers are listed below for brass, normally closed valves. If stainless steel, a J is to be added after the W. If normally open, a K is to be added before the N. Solenoid Valve Parameters Model 2W-040-08N 2W-160-10N 2W-160-15N 2W-200-20N 2W-250-25N 2W-320-32N 2W-400-40N 2W-500-50N Thread Connection (NPT) 1/4″ 3/8″