48V 45A MPPT Solar Charge Controller DC150V 12V 24V 48V Auto Max PV Input 2440W
Specifications
| Return Shipping Will Be Paid By | Seller |
| All Returns Accepted | Returns Accepted |
| Item Must Be Returned Within | 30 Days |
| Brand | SOLAFANS |
| Type | Charger/Inverter |
| Power Source | Solar |
| Voltage | 48V/60V/72V/96V |
| Model | SF9645A |
| MPN | Does not Apply |
| Features | Corrosion Resistant |
Brand new in original graphic box. Ships right away in the USA Tracking per second MPPT solar charge controller 45A MPPT solar charger with dead battery reactivation PV input voltage range 12V battery (DC18V - DC150V); 24V battery (DC36V - DC150V); 48V battery (DC60V - DC150V) The input voltage of the PV must be greater than the battery voltage. Max PV power input: 12V (610W), 24V (1220W), 48V (2440W) / Voltage range identified by the system: 12V SystemDC9V~DC15V 24V SystemDC18V~30V) 48V SystemDC36V~DC60V This SF4845A supports12V / 24V / 36V / 48V battery votlage, 36V needs manual setting. Protections: over charge, over discharge,reverse connection, over voltage, short circuit, reverse current, high temperature, low or over voltage input recovery etc. Technical Parameter New function: battery re-activation, supports 12V/24V/36V/48V, and 36V needs manual set. MPPT Charging mode: MPPT, Equalizing charging (lead acid / GEL/ Liquid), float charging. Batteries support: lead acid, sealed, Gel, AGM, lithium battery etc. Software start-up time: 10s, noise: 50dB, Temperature coefficient: 0.02% / . Automatic temperature compensation: 14.2V - (highest temperature -25) * 0.3%. Temperature protection: 85, altitude: 0~3000m. Smell: No harmful smell, atmospheric pressure: 70~106kPa, Humidity: 0 ~90% RH (not condensation). Environment temperature: -20 ~ +40, Storage temperature: -40 ~ +70. Protection: over charge, over discharge,reverse connection, over voltage, short circuit, high temperature etc. LCD display: PV input voltage, battery type, battery voltage, charge current, daily generation, total generation, language and date, charge status, fault record query, and power curve etc. It is battery re-activation. It can auto wake up the dead batteries through the controller when the sun comes out. You don't need to use the additional tools to activate the battery while it is dead. Please do not connect the inverter / battery / generator... directly with the DC load of controller. Household appliances with motors need to take into account that their instant start power is 3-5 times. The DC load has PV control, time control and auto control. 100 % fully load burn-in testing MPPT controllers and inverters have many intelligent protection functions and new working modes. 48V 45A MPPT Solar Energy Charge Controller Working Voltage DC150V 12V 24V 48V Auto Max PV Input 2440W for Selectable Batteries